BUSINESS UNIT n Project Description Eligible Green Category Eligible Category KPI UM 2006/2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022
BU AMBIENTE Termovalorizzatore per produzione calore per tlr – Comune di Parma Energy efficiency Cogeneration Plant PES Primary Energy Saving Indicator per operating year [%] % 11 17 17 17 17
1 Renewable energy share in percent on total
Thermal energy recovered from waste to Parma DH network in MWh per operating year
%
MWh
27
103
49
130
49
133
49
150
49
151
Termovalorizzatore per produzione calore per tlr – Comune di Piacenza Energy efficiency Cogeneration Plant PES Primary Energy Saving Indicator per operating year [%] % 25 25 25 25
2 Renewable energy share in percent on total
Thermal energy recovered from waste to Piacenza DH network in MWh per operating year
%
MWh
35
55
15
55
15
55
15
55
Raccolta differenziata Torino + Emilia Waste Management Waste Management Efficiency &
3 Efficiency & Recycling Recycling Total sorted waste collection (t) t 635.724 644.444 675.610 721.788 737.163
Total of non sorted waste disposed (t)
Number of bins for sorted waste
t
N
550.903
661.961
528.100
648.491
503.896
648.709
484.128
663.268
488.426
699.065
Volumes of bins for sorted waste (m3
)
Door to door collection system (n)
mc
N
105.278
687.215
111.322
833.069
120.371
998.080
145.345
1.061.847
155.114
1.139.228
Sorted waste collection hubs (n)
Volumes of waste collected in the collection hubs (t)
N
t
112
161.937
112
174.639
112
186.210
117
208.544
117
205.719
BU ENERGIA 4 Accumulatori teleriscaldamento del Bit (TO) Energy efficiency Energy distribution & management
Primary energy saving per operating year [MWh]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
3.855
758
8.220
1.616
10.079
1.981
12.181
2.395
14.372
2.826
12.395
2.437
11.488
2.259
5 Accumulatori teleriscaldamento del Martinetto (TO) Energy efficiency Energy distribution & management
Primary energy saving per operating year [MWh]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
19.261
3.787
20.563
4.043
20.157
3.963
24.363
4.790
28.744
5.651
24.790
4.874
22.977
4.517
6 Accumulatori teleriscaldamento di Mirafiori Nord (TO) Energy efficiency Energy distribution & management
Primary energy saving per operating year [MWh]
Electrical energy produced from renewable non-fossil sources per operating year [MWhe]
MWh
MWh
5.846
45,75
14.372
45,75
12.395
45,75
11.488
45,75
Thermal energy produced from renewable non-fossil sources per operating year [MWht]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
350
1.149
350
2.826
350
2.437
350
2.259
7 Sottostazione scambio termico e pompaggio Lucento Energy efficiency Energy distribution & management
Scambio termico e pompaggio TRM Grugliasco e interconnessione con Electrical energy produced from renewable non-fossil sources per operating year [MWhe]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
18,3
9,37
18,3
9,37
18,3
9,37
18,3
9,37
18,3
9,37
18,3
9,37
8 Grugliasco e Beinasco Energy efficiency Energy distribution & management
Rete di teleriscaldamento di Piacenza, collegamento e stazione di pompaggio Avoided CO2 emissions from fossil sources per operating year [t]
Distributed thermal energy per operating year [MWh]
t
MWh
31.280
145.000
31.280
145.000
31.280
145.000
31.280
145.000
9 Tecnoborgo (PC) Renewable energy Energy Network Development Avoided CO2 emissions from fossil sources per operating year [t] t
Rete di teleriscaldamento di Parma (PR) Renewable energy Energy Network Development Distributed thermal energy per operating year [MWh] MWh 2.384
32.706
2.506
34.389
2.104
28.873
2.504
34.361
2.738
37.568
3.205
43.978
4.232
58.066
4.643
63.701
4.883
66.988
5.002
68.632
5.122
70.276
10 Primary energy saving per operating year [MWh]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
12.813
4.326
13.260
1.551
127.896
16.856
179.722
23.614
199.900
29.523
199.900
29.523
202.519
29.909
204.243
30.164
205.966
30.418
207.689
30.673
207.689
30.673
Distributed thermal energy per operating year [MWh] MWh 176.797 176.815 159.146 188.688 196.691 196.691 200.964 202.660 204.355 204.355
Sviluppo reti teleriscaldamento Torino (TO) Renewable energy Energy Network Development 199.268
11 Primary energy saving per operating year [GWh]
Avoided CO2 emissions from fossil sources per operating year [t]
GWh
t
2.794
1.007.686
2.889
1.092.546
2.270
795.595
2.733
933.086
2.997
1.026.775
3.125
1.070.460
3.176
1.087.995
3.330
1.140.770
3.416
1.170.222
3.479
1.191.843
Sviluppo reti teleriscaldamento Emilia (RE) Renewable energy Energy Network Development Distributed thermal energy per operating year [GWh] GWh 2.192 2.312 1.990 2.109 2.205 2.299 2.336 2.450 2.513 2.559
12 Primary energy saving per operating year [MWh]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
91.780
33.289
92.595
33.585
93.365
33.864
93.883
34.052
94.065
34.118
94.986
34.452
95.553
34.658
96.191
34.889
96.758
35.095
98.175
35.609
98.175
35.609
Mini Hydro La Loggia Renewable energy Mini Hydro Distributed thermal energy per operating year [MWh] MWh 456.566 285.767 384.325 409.932 402.057 405.995 408.418 411.144 413.567 419.625 419.625
13 Mini Hydro Pianchette - Noasca Renewable energy Mini Hydro Electrical energy produced from renewable non-fossil sources per operating year [MWhe]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
3.536
1.810
3.536
1.810
3.536
1.810
3.536
1.810
3.536
1.810
3.536
1.810
3.536
1.810
3.536
1.810
14 Electrical energy produced from renewable non-fossil sources per operating year [MWhe]
Avoided CO2 emissions from fossil sources per operating year [t]
MWh
t
2020
1034
2020
1034
2020
1034
15 Mini Hydro Giffoni riattivazione impianto Vassi Renewable energy Mini Hydro Electrical energy produced from renewable non-fossil sources per operating year [MWhe] MWh 1837 1837 1837
Impianti Fotovoltaici Enìa Solaris presso Brindisi Renewable energy Solar Avoided CO2 emissions from fossil sources per operating year [t] t 940 940 940
IREN RINNOVABILI 16 Net produced electricity from renewable non-fossil sources per operating year (kWh)
Avoided CO2 emissions from fossil sources per operating year [t]
kWh
t
3.491 3.223 6.813.750 6.290.625 6.721.427 7.051.488 6.826.286
3.444
3.613 3.498
17 MIGLIORAMENTO IMPIANTI GENOVA Waste Water Treatment Waste Water Treatment upgrades Treated population equivalent (potential) (n)
Analytic parameters (Abb % BOD, Abb % COD, Abb % SST, Abb % Ntot, Abb % Ptot)
N
%
160.000 160.000 196.000 196.000 196.000 231.000 231.000 236.000 326.000 423.000 423.000
MIGLIORAMENTO IMPIANTI REGGIO EMILIA Waste Water Treatment Waste Water Treatment upgrades Volumes of water destined to irrigation re-usage / Volumes of total treated water % 0 18% 28% 28% 28% 28% 28% 28%
18 Treated population equivalent (potential) (n)
Analytic parameters (Abb % BOD, Abb % COD, Abb % SST, Abb % Ntot, Abb % Ptot)
N 19350 19350 19350 20250 20250 24250 24250 38850 38850 38850 38850
19 MIGLIORAMENTO IMPIANTI DI PIACENZA Waste Water Treatment Waste Water Treatment upgrades Treated population equivalent (potential) (n) N 17360 17360 17360 19500 19500 23500 23500 23500 23500 23500 23500
BU RETI 20 MIGLIORAMENTO IMPIANTI DI PARMA Waste Water Treatment Waste Water Plant Upgrades Analytic parameters (Abb % BOD, Abb % COD, Abb % SST, Abb % Ntot, Abb % Ptot) %
CELSIUS - Impianto di turboespansione cogenerativa Energy efficiency Cogeneration Plant Treated population equivalent (potential) (n)
Analytic parameters (Abb % BOD, Abb % COD, Abb % SST, Abb % Ntot, Abb % Ptot)
N
%
10400 10400 11650 11650 11900 11900 14000 14000 14000 14000 14000
21 Net produced electricity from renewable non-fossil sources per operating year (kWh)
Avoided CO2 emissions from fossil sources per operating year [t]
kWh
t
1.200 1.200 5.100.000 5.100.000 5.100.000 5.100.000 5.100.000
1.200
1.200 1.200
22 Investimenti idroelettrici Renewable energy Mini Hydro Net produced electricity from renewable non-fossil sources per operating year (kWh)
Avoided CO2 emissions from fossil sources per operating year [t]
kWh
t
11.930 11.930 11.930 12.680 23.238.000 23.238.000 23.238.000 24.699.000 25.916.000 32.653.000 34.404.000 36.453.000 36.453.000 36.453.000
13.305
16.763 17.662 18.714 18.714 18.714